Abstract :
Lead glass counters made of wedge shaped blocks of SF6 were tested with positrons at SLAC. The beam energy ranged from 2-17.5 GeV. Energy dependence and beam position dependence of pulse height and energy resolution were studied with lead glass blocks of various lengths. The effect of a BK-7 light guide on pulse height was clearly observed. Degradation of the energy resolution due to aluminum absorbers of various lengths was investigated. A mesh type photomultiplier was also tested.
Keywords :
Counting circuits; Energy resolution; Glass; Particle beams; Photomultipliers; Positrons; Pulse measurements; Radiation detectors; Sulfur hexafluoride; Testing;