Abstract :
Prebreakdown currents at AC are mainly determined by emission currents, if the capacitive current component is compensated. Under certain conditions, which are dealt with in this study, HF (high-frequency) impulse currents are superimposed. The shape of the HF impulse current curve as a function of time was recorded with a high time resolution. The steepness of relevant current jumps has been evaluated. On the basis of the results the phenomenon of HF impulse currents is interpreted as a consequence of changing gas attachment to the metallic electrodes
Keywords :
electric breakdown; vacuum tubes; AC voltage; HF impulse current; capacitive current component; current jumps; emission currents; gas attachment; metallic electrodes; time resolution; vacuum tubes; Circuit testing; Current measurement; Cutoff frequency; Electrodes; Electron tubes; Hafnium; Pressure measurement; Vacuum systems; Valves; Voltage;
fLanguage :
English
Journal_Title :
Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9367
Type :
jour
DOI :
10.1109/14.46316