• DocumentCode
    872855
  • Title

    Cubic temperature dependence for SAWs on X-cut quartz

  • Author

    Webster, Richard T. ; Silva, Jose H.

  • Author_Institution
    Rome Air Dev. Center, Hanscom AFB, MA, USA
  • Volume
    35
  • Issue
    3
  • fYear
    1988
  • fDate
    5/1/1988 12:00:00 AM
  • Firstpage
    386
  • Lastpage
    389
  • Abstract
    A cubic dependence of frequency on temperature has been experimentally observed for surface-acoustic-wave (SAW) delay lines fabricated on X-cut quartz. The SAWs propagate on the X-cut surface in a direction between the positive Y direction and the Z direction, 33.44 degrees from the +Y axis. An experimental system is described for measuring the temperature sensitivity of the delay lines. The measurements show that the relative position of the delay-line transducers has a strong influence on both the frequency versus temperature curve and the insertion loss versus temperature curve.<>
  • Keywords
    delay lines; surface acoustic wave devices; SAW; X-cut quartz; delay lines; frequency; insertion loss; sensitivity; temperature dependence; transducers; Delay lines; Frequency measurement; Loss measurement; Position measurement; Sawing machines; Surface acoustic waves; Temperature dependence; Temperature measurement; Temperature sensors; Transducers;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/58.20459
  • Filename
    20459