Title :
Electrical breakdown of small air gaps bounded by dielectric surfaces using 500/3000 μs surges
Author :
Densley, R.J. ; Salvage, B.
Author_Institution :
Queen Mary College, Department of Electrical Engineering, London, UK
fDate :
7/1/1967 12:00:00 AM
Abstract :
Measurement of the 50% impulse-discharge stress, the apparent discharge magnitude and the total time lag of discharges in air-filled cavities in polythene, using 500/3000 μs surges, is described. The discharge stress is lower and the total time lag greater than with 1/50 μs impulses. With repeated discharges, both are reduced.
Keywords :
air; electric breakdown; impulse testing; insulation testing; plastics; polymers;
Journal_Title :
Electronics Letters
DOI :
10.1049/el:19670240