DocumentCode :
872941
Title :
Performance of Reverse Electrode HPGE Coaxial Detectors after Light Damage by Fast Neutrons
Author :
Raudorf, Thomas W. ; Trammell, Rex C. ; Wagner, Sanford ; Pehl, Richard H.
Author_Institution :
EG&G ORTEC 100 Midland Road Oak Ridge, Tennessee 37830
Volume :
31
Issue :
1
fYear :
1984
Firstpage :
253
Lastpage :
257
Abstract :
Several reverse electrode HPGe coaxial detectors fast neutron-damaged to various fluences were annealed at room temperature for varying periods of time. For comparison, in one case a dry ice temperature anneal was made. The result of these annealings on the energy resolution at 1.33 MeV was measured. The effect of source intensity and energy on the energy resolution and line shape are discussed.
Keywords :
Annealing; Coaxial components; Detectors; Electrodes; Energy measurement; Energy resolution; Ice; Neutrons; Shape; Temperature;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1984.4333257
Filename :
4333257
Link To Document :
بازگشت