Modification of the phased-tracking method for reduction of artifacts in estimated artery wall deformation
Author :
Hasegawa, Hideyuki ; Kanai, Hiroshi
Author_Institution :
Dept. of Electron. Eng., Tohoku Univ., Sendai
Volume :
53
Issue :
11
fYear :
2006
fDate :
11/1/2006 12:00:00 AM
Firstpage :
2050
Lastpage :
2064
Abstract :
Noninvasive measurement of mechanical properties, such as elasticity, of the arterial wall, is useful for diagnosis of atherosclerosis. For assessment of mechanical properties, it is necessary to measure the deformation of the arterial wall. In this study, a modification of the previously proposed phased-tracking method was conducted to improve measurement of the small change in thickness (deformation) of the arterial wall due to the heartbeat. In our previous method, a set of two points along an ultrasonic beam was initially assigned, and the change in thickness of the layer between these two points during an entire cardiac cycle was estimated. In motion estimation with ultrasound, the motion of an interface or a scatterer, which generates an echo, can be obtained by estimating the change in time delay of the echo. For example, in the case of a carotid artery of a healthy subject, there are only two dominant echoes from the lumen-intima and media-adventitia interfaces. Thus, only the displacements of the lumen-intima and media-adventitia interfaces can be estimated, which means that ultrasound can estimate only the change in distance (thickness) between these two interfaces. However, even in this case, our previous method gives different estimates of the change in thickness, depending on the depths (positions in the arterial radial direction) of the two initially assigned points. In this study, modifications of the previous method in terms of the strategy for assignment of layers and the required thickness of an assigned layer were made to reduce such an artificial spatial variation in the estimated changes in thickness. Using the proposed method, errors in estimated changes in thickness were reduced from 21.2 plusmn 24.1% to 0.19 plusmn 0.04% (mean plusmn standard deviation) in simulation experiments. As in the case of the simulation experiments, the spatial variation in estimated changes in thickness also was reduced in in vivo experiments in a carotid artery of - - a healthy subject and in vitro experiments using two excised, diseased arteries
Keywords :
biomechanics; biomedical ultrasonics; blood vessels; deformation; delays; diseases; elasticity; medical image processing; motion estimation; arterial radial direction; arterial wall; artifact reduction; atherosclerosis diagnosis; cardiac cycle; carotid artery; elasticity; estimated artery wall deformation; excised diseased arteries; heartbeat; lumen-intima interface; mechanical properties; media-advertitia interface; motion estimation; phased-tracking method; time delay; ultrasonic beam; ultrasound; Atherosclerosis; Carotid arteries; Elasticity; Mechanical factors; Mechanical variables measurement; Motion estimation; Noninvasive treatment; Phase estimation; Ultrasonic imaging; Ultrasonic variables measurement;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2006.145
Filename :
4037213
Link To Document :
بازگشت