• DocumentCode
    873527
  • Title

    Study of viscoelastic effect on the frequency shift of microcantilever chemical sensors

  • Author

    Sampath, Uttara ; Heinrich, Stephen M. ; Josse, Fabien ; Lochori, F. ; Dufour, Isabelle ; Rebiere, Dominique

  • Author_Institution
    Microsensor Res. Laboratory, Marquette Univ., Milwaukee, WI
  • Volume
    53
  • Issue
    11
  • fYear
    2006
  • fDate
    11/1/2006 12:00:00 AM
  • Firstpage
    2166
  • Lastpage
    2173
  • Abstract
    Microcantilevers coated with a chemically sensitive layer are increasingly being used in chemical detection systems. The sensitive coating, often a polymer, absorbs specific molecules, which can be detected by monitoring the shift in the mechanical resonant frequency. Usually. the frequency shift resulting from molecular absorption is interpreted as a mass loading effect. However, mass loading is not the only effect that has an impact on the frequency shift; the viscoelastic properties of the sensitive coating also are affected by the sorption process. Sorption-induced modulus changes are typically difficult to characterize. However, it is known that the sorption of analyte molecules in a polymer coating results in the plasticization of the coating. In most cases, the polymer becomes more rubbery with increasing concentration of analyte molecules, i.e., the coating becomes softer with increasing loss modulus, and the storage modulus decreases. Using a new analytical model developed for the resonant frequency expression of a hybrid microcantilever (elastic base and viscoelastic layer), the effects of the modification of the storage and loss moduli of the sensitive layer on the resonant frequency are examined. The main conclusion of this analytical study is that, even if the sensitive coating moduli are small compared to the base cantilever´s Young´s modulus, the effect of the change in the viscoelastic coating properties could contribute significantly to the overall frequency shift (8-23% in the simulations depending on the coating thickness, with even higher contributions for other sets of problem parameters)
  • Keywords
    Young´s modulus; cantilevers; chemical sensors; elasticity; micromechanical devices; plasticity; polymer films; sorption; viscoelasticity; Young´s modulus; chemically sensitive layer; frequency shift; loss modulus; microcantilever chemical sensors; molecular absorption; plasticization; storage modulus; viscoelastic coating; viscoelastic effect; Absorption; Analytical models; Chemical sensors; Chemical transducers; Coatings; Elasticity; Monitoring; Polymer films; Resonant frequency; Viscosity;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2006.156
  • Filename
    4037224