DocumentCode :
873836
Title :
Development of a High-Precision Calorimeter for Measuring Power Loss in Electrical Machines
Author :
Cao, Wenping ; Bradley, Keith J. ; Ferrah, Azzeddine
Author_Institution :
Sch. of Sci. & Technol., Univ. of Teesside, Middlesbrough
Volume :
58
Issue :
3
fYear :
2009
fDate :
3/1/2009 12:00:00 AM
Firstpage :
570
Lastpage :
577
Abstract :
This paper is concerned with the development of a high-precision 30-kW (40-hp) calorimeter and is specifically focused on how experimental errors resulting from calorimeter design and operating procedures are eliminated or mitigated. A complete calibration for the calorimetric system using a DC heater is conducted, and two induction motors rated at 5.5 and 30 kW (7 and 40 hp, respectively) are carefully tested both within and outside of the calorimeter. Loss segregation is in accordance with the IEEE 112 method B. Experimental results for the comparison of calorimetric and input-output methods clearly confirm the effectiveness of the calorimeter in terms of accurate power loss measurement. The accuracy of the calorimeter is approximately 5.6 W in the measurement of power loss of up to 4.5 kW with a resolution of 0.1 W.
Keywords :
calibration; calorimeters; induction motors; loss measurement; machine testing; power measurement; DC heater; IEEE 112 method; calibration; electrical machines; high-precision calorimeter design; induction motors; loss segregation; power 30 kW; power 5.5 kW; power loss measurement; Calorimetry; heat run test; heat transfer; induction motor; loss measurement; power loss;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2008.2005083
Filename :
4633679
Link To Document :
بازگشت