• DocumentCode
    873992
  • Title

    Sensitivity of 2nd-order Sallen-key-type active RC filters

  • Author

    Saraga, W.

  • Volume
    3
  • Issue
    10
  • fYear
    1967
  • fDate
    10/1/1967 12:00:00 AM
  • Firstpage
    442
  • Lastpage
    444
  • Abstract
    The sensitivity, to ¿¿1 (where ¿ is the open-loop amplifier gain), of the Q factor of a 2nd-order Sallen-Key circuit can be reduced from the conventional value 2Q2/¿ to 3Q/¿ by increasing the closed-loop gain from 1 to 4/3. However, this increases the sensitivity to passive-element variations. An optimum engineering solution is found by minimising, for given maximum component variations, the resulting variation of Q, rather than the sensitivities. This makes single-amplifier circuits usable for higher Q factors than previously, which is of particular interest for microelectronic realisations of such circuits.
  • Keywords
    circuit theory; filters;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19670350
  • Filename
    4207398