DocumentCode
874373
Title
Comparison of reliability of conventional and rapid aging methods for insulating materials
Author
Yingsuo, Zhang ; Yi, Bai ; Yanxiu, Ma
Author_Institution
Xi´´an Res. Inst. of Insulating Mater., China
Volume
27
Issue
6
fYear
1992
fDate
12/1/1992 12:00:00 AM
Firstpage
1159
Lastpage
1165
Abstract
It is shown that the conventional aging (CA) method of insulating materials is only an approximation, and simulates the actual service of insulation. Since the test is complex and uncertain, CA cannot be absolute. Although most rapid thermal endurance test methods of insulating materials are based on CA, once established, they are independent test methods. Further, the dispersion of CA data is large and repeating the tests is difficult due to its long time and high costs. Rapid methods, such as thermogravimetric point slope (TPS), have smaller scatter, higher success ratio, and good accuracy and are easy to repeat. Therefore, taken as a whole, the reliability of TPS may well be identical with, or even better than, that of CA for determining the thermal endurance properties of insulating materials
Keywords
ageing; insulation testing; life testing; materials testing; organic insulating materials; reliability; accelerated testing; accuracy; conventional aging method; data dispersion; data scatter; independent test methods; insulating materials aging; rapid aging methods; rapid thermal endurance test methods; reliability; repeatability; success ratio; thermogravimetric point slope method; Aging; Dielectrics and electrical insulation; Insulation testing; Materials reliability; Materials testing; Resistance heating; System testing; Temperature; Thermal stresses; Uncertainty;
fLanguage
English
Journal_Title
Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
0018-9367
Type
jour
DOI
10.1109/14.204867
Filename
204867