Title :
A robust method for estimating respiratory flow using tracheal sounds entropy
Author :
Yadollahi, Azadeh ; Moussavi, Zahra M K
Author_Institution :
Dept. of Electr. Eng., Sharif Univ. of Technol., Tehran, Iran
fDate :
4/1/2006 12:00:00 AM
Abstract :
The relationship between respiratory sounds and flow is of great interest for researchers and physicians due to its diagnostic potentials. Due to difficulties and inaccuracy of most of the flow measurement techniques, several researchers have attempted to estimate flow from respiratory sounds. However, all of the proposed methods heavily depend on the availability of different rates of flow for calibrating the model, which makes their use limited by a large degree. In this paper, a robust and novel method for estimating flow using entropy of the band pass filtered tracheal sounds is proposed. The proposed method is novel in terms of being independent of the flow rate chosen for calibration; it requires only one breath for calibration and can estimate any flow rate even out of the range of calibration flow. After removing the effects of heart sounds (which distort the low-frequency components of tracheal sounds) on the calculated entropy of the tracheal sounds, the performance of the method at different frequency ranges were investigated. Also, the performance of the proposed method was tested using 6 different segment sizes for entropy calculation and the best segment sizes during inspiration and expiration were found. The method was tested on data of 10 healthy subjects at five different flow rates. The overall estimation error was found to be 8.3 ± 2.8% and 9.6 ± 2.8% for inspiration and expiration phases, respectively.
Keywords :
band-pass filters; bioacoustics; calibration; entropy; medical signal processing; pneumodynamics; band pass filtered tracheal sounds; calibration flow; expiration; heart sounds; inspiration; respiratory flow estimation; respiratory sounds; tracheal sounds entropy; Calibration; Entropy; Estimation error; Fluid flow measurement; Frequency estimation; Heart; Inductance measurement; Pressure measurement; Robustness; Testing; Entropy; flow estimation; heart sounds; tracheal sounds; Adult; Algorithms; Child; Computer Simulation; Diagnosis, Computer-Assisted; Entropy; Female; Humans; Lung; Male; Models, Biological; Respiratory Mechanics; Respiratory Sounds; Rheology; Sound Spectrography; Trachea;
Journal_Title :
Biomedical Engineering, IEEE Transactions on
DOI :
10.1109/TBME.2006.870231