Title :
A DC voltage is equivalent to two traveling waves on a lossless, nonuniform transmission line
Author_Institution :
AT&T Bell Lab., Princeton, NJ, USA
fDate :
3/1/1993 12:00:00 AM
Abstract :
A static DC voltage can be treated as two traveling waves propagating in opposite directions of a lossless, nonuniform transmission line. The amplitudes of these two traveling waves are a function of the characteristic impedance of signal line. The concept of two traveling waves is applied to a time-domain-scattering-parameter analysis in a lossless, nonuniform transmission line terminated with nonlinear loads.<>
Keywords :
S-parameters; electric impedance; electric potential; time-domain analysis; transmission line theory; DC voltage; characteristic impedance; lossless line; nonlinear load termination; nonuniform transmission line; signal line; time-domain-scattering-parameter analysis; traveling waves; Capacitance; Distributed parameter circuits; Impedance; Inductance; Propagation losses; Space exploration; Steady-state; Time domain analysis; Transmission lines; Voltage;
Journal_Title :
Microwave and Guided Wave Letters, IEEE