DocumentCode :
876448
Title :
The Available Power of a Matched Generator from the Measured Load Power in the Presence of Small Dissipation and Mismatch of the Connecting Network (Correspondence)
Author :
Sucher, M. ; Sweet, L.O.
Volume :
5
Issue :
2
fYear :
1957
fDate :
4/1/1957 12:00:00 AM
Firstpage :
167
Lastpage :
168
Abstract :
It is sometimes necessary to determine the available power of a matched generator in terms of the power dissipated in a load when the load is connected to the generator by means of a slightly mismatched 4-pole having small loss. (A piece of waveguide or short length of coaxial line could exemplify such a 4-poIe; the discontinuities at flanges or at connectors and supporting beads could give rise to the slight mismatch.)
Keywords :
Admittance; Aerospace engineering; Aircraft propulsion; Equations; Frequency; Iris; Joining processes; Power generation; Power measurement; Reflection;
fLanguage :
English
Journal_Title :
Microwave Theory and Techniques, IRE Transactions on
Publisher :
ieee
ISSN :
0097-2002
Type :
jour
DOI :
10.1109/TMTT.1957.1125127
Filename :
1125127