Title :
Experimental investigation of EM noise environment surrounding detector systems in Swedish railways
Author :
Wisten, A. ; Niska, S. ; Ekman, J. ; Björklöf, D. ; Delsing, J.
Author_Institution :
Dept. of Comput. Sci. & Electr. Eng., Lulea Univ. of Technol., Sweden
fDate :
3/2/2006 12:00:00 AM
Abstract :
The close environment of railway tracks is heavily polluted by electromagnetic noise from the railway system itself. The reliability of railway signalling, communication, and control systems depends on good immunity to electromagnetic noise. There are sometimes false detector signals indicating non-existing flat wheels and ghost trains. A possible reason for detector failures is interference by transient voltage peaks in the detector system. Thus characterisation has been made of the electromagnetic environment around the detector system located at the track. The investigation shows that the typical electromagnetic environment is a combination of broadband low-level noise, and rare fast transients of potentially harmful amplitudes.
Keywords :
electromagnetic interference; failure analysis; railway electrification; reliability; sensors; signalling; Swedish railway; broadband low-level noise; detector failure; detector signal; electromagnetic noise; ghost train; nonexisting flat wheel; pollution; railway communication; railway control system; railway signalling reliability; railway track; transient voltage interference;
Journal_Title :
Electric Power Applications, IEE Proceedings -
DOI :
10.1049/ip-epa:20050040