Title :
Leak detection for transport pipelines based on autoregressive modeling
Author :
Wang, Guizeng ; Dong, Dong ; Fang, Chongzhi
Author_Institution :
Dept. of Autom., Tsinghua Univ., Beijing, China
fDate :
2/1/1993 12:00:00 AM
Abstract :
A leak detection method based on autoregressive modeling is proposed. It requires only four pressure measurements, two at each end of the pipeline. A leak above 0.5% can be reliably and quickly detected by analyzing the time sequences of the pressure gradient at the inlet and outlet of the pipeline. It can be easily implemented because the computational expenditure is small. Its effectiveness has been verified by tests on a 10-mm-diameter, 120-m-long experimental water pipeline
Keywords :
leak detection; pressure measurement; random processes; 10 mm; 120 m; Kullback information; autoregressive modeling; diameter; inlet; outlet; pressure gradient; pressure measurements; probability; time sequence analysis; time sequences; transport pipelines; Capacitance; Capacitors; Electrodes; Gas insulation; Insulators; Leak detection; NIST; Pipelines; Pressure measurement; Voltage;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on