• DocumentCode
    877331
  • Title

    Precision average-sensing AC/DC converters

  • Author

    Martens, Olev ; Pungas, Toom

  • Author_Institution
    Enari Electronics Ltd., Tallinn, Estonia
  • Volume
    42
  • Issue
    1
  • fYear
    1993
  • fDate
    2/1/1993 12:00:00 AM
  • Firstpage
    71
  • Lastpage
    73
  • Abstract
    Various configurations of average-sensing AC/DC converters for precision AC voltage measurements are described. Due to the unique electrical configurations in which the influence of the inaccuracy of ratio resistors is suppressed, these converters have high accuracy (better than 0.01%) and resolution (0.0001%) at medium frequencies. Their frequency range is from 10 Hz to 1 MHz, with a settling time less than 1 s
  • Keywords
    power convertors; signal processing equipment; voltage measurement; 1 s; 10 Hz to 1 MHz; AC voltage measurements; average-sensing AC/DC converters; ratio resistors; settling time; Capacitors; Circuits; DC-DC power converters; Diodes; Low pass filters; Negative feedback; Operational amplifiers; Rectifiers; Resistors; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.206687
  • Filename
    206687