DocumentCode
878001
Title
The TEV I Beam Position Monitor System
Author
Holmes, S.D. ; McCarthy, J.D. ; Sommers, S.A. ; Webber, R.C. ; Zagel, J.R.
Author_Institution
Fermi National Accelerator Laboratory P.O. Box 500 Batavia, IL 60510
Volume
32
Issue
5
fYear
1985
Firstpage
1927
Lastpage
1929
Abstract
The TeV I Beam Position Monitor System is described. This system is designed to provide accurate orbit information during both the commissioning and operational phases of the Fermilab Antiproton Source. The system is required to provide position information with submillimeter resolution for both single turn orbit measurements with beam intensities in the range 1Ã109 to 1Ã1011, and multiple turn (closed orbit) measurements with beam intensities in the range 1Ã107 to 5Ã1011. The system has already been used during commissioning of the Debuncher to measure the first turn through the ring, the horizontal and vertical betatron tunes, the closed orbit, the dispersion, aperture, and chromaticity. During normal antiproton operation the system will be used to monitor beam position throughout the accumulation process.
Keywords
Apertures; Bandwidth; Capacitance; Extraterrestrial measurements; Frequency; Low-frequency noise; Monitoring; Position measurement; Signal processing; Signal resolution;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1985.4333770
Filename
4333770
Link To Document