Title :
New Beam Diagnostics at GANIL : Very Sensitive Current Transformers in Beam Lines and Counting System of Beam Turns in Cyclotrons
Author :
Loyer, F. ; Andre, T. ; Ducoudret, B. ; Rataud, J.P.
Author_Institution :
GANIL, BP 5027, CAEN Cedex - France
Abstract :
Two new beam diagnostics have been designed and are in operation at GANIL : - To measure very small beam currents without intercepting the beam, transformers have been developped whose resolution is as low as 1 enA. That is obtained by ussing synchronous detectors locked on the PIG source pulsation and by reducing the noise level. - As the accelerated orbits in the second main cyclotron are overlapping one another, we cannot count the number of turns by a classical moving probe. Therefore we compute the cross-correlation function of the beam signals detected on inductive probes at the input and the output of the cyclotron. Due to the natural random beam structure, this cross-correlation function has a sharp maximum for the value of the beam time of flight. Thence the right number of beam turns can be calculated.
Keywords :
Acceleration; Current measurement; Current transformers; Cyclotrons; Detectors; Extraterrestrial measurements; Noise level; Orbits; Probes; Signal detection;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1985.4333773