• DocumentCode
    878082
  • Title

    Internal Polarimeters for the Polarized Proton Beam at the KEK 12 GeV PS

  • Author

    Sato, Hikaru ; Hiramatsu, Shigenori ; Toyama, Takeshi ; Arakawa, Dai ; Sakamoto, Hiroshi ; Imai, Ken-ichi ; Tamura, Norio

  • Author_Institution
    National Laboratory for High Energy Physics Oho-machi, Tsukuba-gun, Ibaraki-ken, 305, Japan
  • Volume
    32
  • Issue
    5
  • fYear
    1985
  • Firstpage
    1950
  • Lastpage
    1952
  • Abstract
    An internal polarimeter was constructed to detect the beam polarization in KEK proton synchrotron (PS) from TP = 500 MeV to 12 GeV. The polarimeter was installed in the main ring and successfully used for the measurement of the beam polarization at 500 MeV. We report the design and the performance of this polarimeter and the results of this first measurement. In addition to that, we also report the design of another internal polarimeter for monitoring the depolarization in the booster.
  • Keywords
    Acceleration; Energy measurement; Particle beams; Polarization; Polyethylene; Proton accelerators; Resonance; Scattering; Structural beams; Synchrotrons;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1985.4333777
  • Filename
    4333777