DocumentCode :
878260
Title :
High Resolution Beam Profile Monitors in the SLC
Author :
Ross, M.C. ; Seeman, J.T. ; Jobe, R.K. ; Sheppard, J.C. ; Stiening, R.F.
Author_Institution :
Stanford Linear Accelerator Center Stanford University, Stanford, California, 94305
Volume :
32
Issue :
5
fYear :
1985
Firstpage :
2003
Lastpage :
2005
Abstract :
In the SLC linac, low emittance beams with typical transverse dimensions less than 0.2 mm must be accelerated without effective emittance growth. In order to monitor this we have installed a high resolution beam profile monitor system which consists of an aluminum target covered with a fine-grained phosphor, a magnifying optical system, a television camera and video signal recording electronics. The image formed when the beam strikes the phosphor screen is viewed on a CRT monitor at the console and selected horizontal and vertical slices of the beam spot intensity are recorded. A 20 MHz transient waveform recorder is used to sample and digitize the raw video signal along the selected slice. The beam width is determined by fitting the background subtracted data to a Gaussian. Beam spots less than 6 × 3 mm can be viewed. Beam spot sizes ¿x,y < 80¿m have been measured.
Keywords :
Acceleration; Aluminum; Cameras; Linear particle accelerator; Optical recording; Particle beams; Phosphors; Signal resolution; Stimulated emission; TV;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1985.4333795
Filename :
4333795