• DocumentCode
    879189
  • Title

    Impacts of time-of-use rates on the optimal sizing and operation of cogeneration systems

  • Author

    Asano, H. ; Sagai, S. ; Imamura, E. ; Ito, K. ; Yokoyama, R.

  • Author_Institution
    Central Res. Inst. of Electr. Power Ind., Tokyo, Japan
  • Volume
    7
  • Issue
    4
  • fYear
    1992
  • fDate
    11/1/1992 12:00:00 AM
  • Firstpage
    1444
  • Lastpage
    1450
  • Abstract
    For customers with a cogeneration system (CGS), a mixed-integer programming and nonlinear programming model was used to examine effects of time-of-use (TOU) rates on the optimal operation of the constituent equipment as well as the optimal sizing. Three customers were selected for case studies: a hotel, a hospital, and an office building. Effects of an on-peak/off-peak energy charge ratio on purchased power share in the total electricity demand were saturated at the ratio of 5. As the energy charge ratio was raised, cheaper off-peak power substituted for city gas and the operating cost decreased. The responses of the hotel and the hospital were similar. The simulation results indicated that properly designed TOU rates can provide commercial customers an incentive to operate a CGS with an appropriate mix of self-generation and commercial power
  • Keywords
    cogeneration; integer programming; nonlinear programming; tariffs; cogeneration systems; electricity demand; hospital; hotel; mixed-integer programming; nonlinear programming model; office building; on-peak/off-peak energy charge ratio; optimal sizing; purchased power share; time-of-use rates; Absorption; Cogeneration; Contracts; Electrical equipment industry; Hospitals; Indium tin oxide; Power generation; Refrigeration; Space heating; Water heating;
  • fLanguage
    English
  • Journal_Title
    Power Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8950
  • Type

    jour

  • DOI
    10.1109/59.207366
  • Filename