• DocumentCode
    879325
  • Title

    Optimal illumination for three-image photometric stereo using sensitivity analysis

  • Author

    Spence, A.D. ; Chantler, M.J.

  • Author_Institution
    Sch. of Math. & Comput. Sci., Heriot-Watt Univ., Edinburgh, UK
  • Volume
    153
  • Issue
    2
  • fYear
    2006
  • fDate
    4/6/2006 12:00:00 AM
  • Firstpage
    149
  • Lastpage
    159
  • Abstract
    The optimal placement of the illumination for three-image photometric stereo acquisition of smooth and rough surface textures with respect to camera noise is derived and verified experimentally. The sensitivities of the scaled surface normal elements are derived and used to provide expressions for the noise variances. An overall figure of merit is developed by considering the image-based rendering (i.e. relighting) of Lambertian surfaces. This metric is optimised numerically with respect to the illumination angles. An orthogonal configuration was found to be optimal. With regard to constant slant, the optimal separation between the tilt angles of successive illumination vectors was found to be 120°. The optimal slant angle was found to be 90° for smooth surface textures and 55° for rough surface textures.
  • Keywords
    image texture; photometry; sensitivity analysis; stereo image processing; Lambertian surfaces; camera noise; image-based rendering; noise variances; optimal illumination; optimal slant angle; rough surface textures; sensitivity analysis; smooth surface textures; three-image photometric stereo;
  • fLanguage
    English
  • Journal_Title
    Vision, Image and Signal Processing, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-245X
  • Type

    jour

  • DOI
    10.1049/ip-vis:20050229
  • Filename
    1610530