Title :
Transverse Emittance of a 2.0-MeV RFQ Beam with High Brightness
Author :
Sander, O.R. ; Boicourt, G.P. ; Cottingame, W.B.
Author_Institution :
AT-2, MS H818 Los Alamos National Laboratory, Los Alamos, NM 87545 USA
Abstract :
One major purpose of the accelerator test stand (ATS) is to see if particle simulation codes can correctly predict the output beam parameters of our radiofrequency quadrupole (RFQ) linac. By injecting a very bright 100-keV beam (100 mA, 0.02 ¿.cm.mrad) and comparing the measured output beam parameters with those predicted (using PARMTEQ), we can investigate PARMTEQ´s performance in a high space-charge regime. PARMTEQ has successfully simulated the RFQ beam transmission and energy distribution; it is more difficult to simulate output transverse emittance. Transverse emittance is also difficult to measure because of the high-power-density beam. Special modification of our interceptive slit and collector equipment was required. This paper will compare measured transverse emittances with those predicted.
Keywords :
Brightness; Life estimation; Linear particle accelerator; Particle accelerators; Particle beam injection; Particle beam measurements; Particle beams; Predictive models; Radio frequency; Testing;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1985.4333989