• DocumentCode
    880360
  • Title

    A high-Q Fabry-Perot interferometer for water vapor absorption measurements in the 100 Gc/s to 300 Gc/s frequency range

  • Author

    Valkenburg, E.P. ; Derr, V.E.

  • Author_Institution
    Martin Company, Orlando, Fla.
  • Volume
    54
  • Issue
    4
  • fYear
    1966
  • fDate
    4/1/1966 12:00:00 AM
  • Firstpage
    493
  • Lastpage
    498
  • Abstract
    The investigation of atmospheric losses in the far-infrared and submillimeter wavelength regions has been pursued from both ends of the spectrum, i.e., from the infrared using IR spectroscopic techniques, and from the microwave region using coherent, high resolution spectroscopic methods. This paper describes the design of a Fabry-Perot semi-confocal interferometer, and its application to the measurement of atmospheric gas losses using coherent sources in the 100 Gc/s to 300 Gc/s frequency range. The tunable interferometer exhibits Q´s as large as 3 × 105at 300 Gc/s, permitting the measurement of loss with a sensitivity of tan δ= 10-8and an error of five percent or less.
  • Keywords
    Atmospheric measurements; Atmospheric waves; Electromagnetic wave absorption; Fabry-Perot interferometers; Frequency measurement; Infrared spectra; Loss measurement; Spectroscopy; Submillimeter wave technology; Wavelength measurement;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEEE
  • Publisher
    ieee
  • ISSN
    0018-9219
  • Type

    jour

  • DOI
    10.1109/PROC.1966.4763
  • Filename