• DocumentCode
    880521
  • Title

    Extensive performance studies for the ATLAS BIS-MDT precision muon chambers with cosmic rays

  • Author

    Alexopoulos, T. ; Avramidou, R. ; Bratzler, U. ; Cernoch, C. ; Dris, M. ; Fassouliotis, D. ; Filippas, T.A. ; Fokitis, E. ; Gazis, E.N. ; Ioannou, P. ; Katsoufis, E.C. ; Kourkoumelis, Ch. ; Krepouri, A. ; Liolios, T. ; Maltezos, S. ; Manolopoulou, M. ; Pa

  • Author_Institution
    Phys. Dept., Nat. Tech. Univ. of Athens, Greece
  • Volume
    50
  • Issue
    6
  • fYear
    2003
  • Firstpage
    2420
  • Lastpage
    2425
  • Abstract
    ATLAS (a toroidal LHC apparatus) is a general purpose experiment that will start its operation at the large hadron collider (LHC) at CERN in 2007. The ATLAS detector is designed to explore numerous physics processes by recording, measuring, and investigating the products emerging from proton-proton collisions at energies up to 14 TeV. High-precision muon momentum measurement (dp/p∼10% at pT=1 TeV/c) over large areas using monitored drift tube (MDT) chambers is crucial for the ATLAS experiment. More than 1200 MDT chambers, consisting of approximately 370 000 drift tubes, will provide a total coverage of 5500 m2. Three Greek universities have taken the responsibility to construct 130 barrel inner small (BIS)-MDT chambers using 30 000 drift tubes of ∼1.7 m length that have been quality tested before assembly. The design of the muon drift tubes aims at high detection efficiency (>95%) and a spatial single tube resolution of <80 μm. This paper describes the cosmic ray test setup, which has been instrumented in order to verify that the BIS-MDT chamber Module-0 fulfills its design requirements. The analysis of its data shows that the chamber meets these requirements; it has low noise levels, uniform drift properties, good spatial resolution, and high particle detection efficiency.
  • Keywords
    cosmic ray muons; drift chambers; muon detection; position sensitive particle detectors; ATLAS BIS-MDT precision muon chambers; ATLAS detector; BIS-MDT Module-0; Large Hadron Collider; cosmic ray test setup; cosmic rays; drift properties; gas detector; high-precision muon momentum measurement; monitored drift tube chambers; noise levels; particle detection efficiency; proton-proton collisions; spatial resolution; spatial single tube resolution; toroidal LHC apparatus; Area measurement; Cosmic rays; Detectors; Energy measurement; Large Hadron Collider; Mesons; Monitoring; Physics; Spatial resolution; Testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2003.820630
  • Filename
    1263922