DocumentCode
880623
Title
Front-end electronics for the CDF-II time-of-flight system
Author
Chen, C. ; Jones, M. ; Kononenko, W. ; Kroll, J. ; Mayers, G.M. ; Newcomer, F.M. ; Oldeman, R.G.C. ; Usynin, D. ; Van Berg, R.
Author_Institution
Dept. of Phys. & Astron., Univ. of Pennsylvania, Philadelphia, PA, USA
Volume
50
Issue
6
fYear
2003
Firstpage
2486
Lastpage
2490
Abstract
A time-of-flight (TOF) detector has been added to the CDF-II experiment to provide charged kaon identification primarily for neutral B meson flavor determination. The TOF front-end electronics system has 432 channels and is designed to run at the 7.58 MHz clock rate in CDF. The electronics contributes less than 10 ps to the TOF timing resolution of 120 ps, which is dominated by photon statistics. This paper describes the design and implementation of the electronics as well as the in situ performance.
Keywords
B mesons; flavour model; meson detection; nuclear electronics; photomultipliers; scintillation counters; time of flight spectrometers; 7.58 MHz; CDF-II time-of-flight system; TOF detector; TOF front-end electronics system; TOF timing resolution; charged kaon identification; electronics design; in situ performance; neutral B meson flavor determination; photomultiplier; photon statistics; scintillator; Anodes; Clocks; Detectors; Mesons; Photoelectricity; Preamplifiers; Signal processing; Statistics; Timing; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2003.820632
Filename
1263932
Link To Document