• DocumentCode
    880623
  • Title

    Front-end electronics for the CDF-II time-of-flight system

  • Author

    Chen, C. ; Jones, M. ; Kononenko, W. ; Kroll, J. ; Mayers, G.M. ; Newcomer, F.M. ; Oldeman, R.G.C. ; Usynin, D. ; Van Berg, R.

  • Author_Institution
    Dept. of Phys. & Astron., Univ. of Pennsylvania, Philadelphia, PA, USA
  • Volume
    50
  • Issue
    6
  • fYear
    2003
  • Firstpage
    2486
  • Lastpage
    2490
  • Abstract
    A time-of-flight (TOF) detector has been added to the CDF-II experiment to provide charged kaon identification primarily for neutral B meson flavor determination. The TOF front-end electronics system has 432 channels and is designed to run at the 7.58 MHz clock rate in CDF. The electronics contributes less than 10 ps to the TOF timing resolution of 120 ps, which is dominated by photon statistics. This paper describes the design and implementation of the electronics as well as the in situ performance.
  • Keywords
    B mesons; flavour model; meson detection; nuclear electronics; photomultipliers; scintillation counters; time of flight spectrometers; 7.58 MHz; CDF-II time-of-flight system; TOF detector; TOF front-end electronics system; TOF timing resolution; charged kaon identification; electronics design; in situ performance; neutral B meson flavor determination; photomultiplier; photon statistics; scintillator; Anodes; Clocks; Detectors; Mesons; Photoelectricity; Preamplifiers; Signal processing; Statistics; Timing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2003.820632
  • Filename
    1263932