Abstract :
Half-order subharmonic instability, which can occur in closed-loop systems containing an ideal sampler feeding a first-order load, does not occur when the sampler is replaced by a thyristor amplifier with the same d.c. gain. Analysis by the subharmonic describing-function method indicates that both systems are stable and so time domain analyses are presented which account for their behaviour.
Keywords :
stability; thyristor applications;
fLanguage :
English