DocumentCode
883419
Title
Improvement of the High Voltage Properties of the Fermilab Electrostatic Septa
Author
Trbojevic, D. ; Crawford, C. ; Childress, S. ; Tinsley, D.
Author_Institution
Fermi National Accelerator Laboratory P.O. Box 500 Batavia, Illinois 60510
Volume
32
Issue
5
fYear
1985
Firstpage
3074
Lastpage
3076
Abstract
In the Fermilab Tevatron Switchyard proton beam splits are initiated by a wire array electrostatic septum. At 1 TeV energy, and with fields limited to 50 kV/cm, and electrostatic septum more than 20 meters in length is required to produce the required angular separation between the beams for the Proton and Neutrino/Meson lines. New techniques have been investigated that will allow reliable operation at fields above 75 kV/cm with resultant beam line economy. Changes in construction and conditioning procedures have been studied using a short sample of an electrostatic septum.
Keywords
Anodes; Cathodes; Electrodes; Electrostatics; Particle beams; Sparks; Surface cleaning; Testing; Voltage; Wires;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1985.4334279
Filename
4334279
Link To Document