Title :
A Pulsed Septum Magnet for the Fermilab Antiproton Source
Author :
Satti, J.A. ; Holmes, S.D.
Author_Institution :
Fermi National Accelerator Laboratory Batavia, Illinois 60510
Abstract :
A 2 meter curved pulsed septum magnet for use in the Fermilab Antiproton Source is described. The magnet produces a peak field of 6 kGauss at a current of 20,000 Amperes within a 0.4 msec long pulse. The field uniformity obtained is AB/B<0.2% out to 3.8 cm from the copper septum. Power enters the magnet from the center resulting in very simple ends and the magnet incorporates a 0.5 cm steel guard which reduces the field to <1.4 Gauss in the zero-field region. The total septum thickness is 1.3 cm. The vacuum enclosure doubles as the stacking fixture for the magnet laminations allowing easy assembly of a magnet with a 50 m radius of curvature.
Keywords :
Ceramics; Conductors; Copper; Fixtures; Lamination; Magnetic shielding; Rails; Stacking; Steel; Surface resistance;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1985.4334449