Title :
A Precise and Sensitive X-Band Reflecto"meter" Providing Automatic Full-Band Display of Reflection Coefficient
fDate :
7/1/1965 12:00:00 AM
Abstract :
A simple waveguide system has been made for the instantaneous measurement of the magnitude of the reflection coefficient as a function of frequency for the 8.2-12.4 Gc band. Reflection coefficients in the range 1 to 0.001 can be measured on linear scales; above 0.01 the error is less than ±3 per cent, below 0.01 it is estimated to be in the order of ±5 per cent. By using a long line between the unknown impedance and the two wall-current detectors, which act as measuring probes, an audio-frequency voltage has been obtained which is linearly proportional to the amplitude of the unknown reflection coefficient. A third wall-current detector is used as a leveler. The principle is quite simple and can easily be applied for other frequencies or transmission lines.
Keywords :
Couplings; Detectors; Directional couplers; Displays; Energy measurement; Frequency; Microwave radiometry; Pulse measurements; Pulse shaping methods; Reflection;
Journal_Title :
Microwave Theory and Techniques, IEEE Transactions on
DOI :