DocumentCode :
885819
Title :
Details of the Cryogenic System for the Cornell Superconducting R.f. Beam Tests
Author :
Kirchgessner, J. ; Demjanic, P. ; Henderson, C. ; Herb, S. ; Mistry, N. ; Phillips, L. ; Walters, J.
Author_Institution :
Laboratory of Nuclear Studies Cornell University Ithaca, NY 14853
Volume :
32
Issue :
5
fYear :
1985
Firstpage :
3787
Lastpage :
3789
Abstract :
During the course of the most recent and past Superconducting R.F. beam tests in CESR, various techniques and concepts were developed in the implementation of the cryogenic system1,2,3,4. Some of these items will be described and will include, the long liquid helium transfer line, the liquid phase separation, the liquid nitrogen cooling system, feeding the wavequide heat exchangers, the JT valve, the temperature regulation and pumping system, the overall control and monitoring system, large and many indium seals, and mechanical details of the cryostat vessel.
Keywords :
Control systems; Cooling; Cryogenics; Heat pumps; Heat transfer; Helium; Nitrogen; System testing; Temperature control; Valves;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1985.4334503