• DocumentCode
    886870
  • Title

    Ion mobility scanning ion chamber

  • Author

    Cockbaine, D.R.

  • Volume
    140
  • Issue
    2
  • fYear
    1993
  • fDate
    3/1/1993 12:00:00 AM
  • Firstpage
    155
  • Lastpage
    160
  • Abstract
    An aspirated ion chamber measuring from natural atmospheric ion levels of 400*106 ions/m3 to 1.6*1012 ions/m3 over a mobility range of 2.77 to 0.004*10-4 m2/Vs which has been proven for field use, is described.
  • Keywords
    ion mobility; ionisation chambers; power overhead lines; aspirated ion chamber; atmospheric ion levels; high voltage transmission lines; ion concentration 400*106 to 1.6*1012 ions/m3; ion mobility 0.004*10-4 to 2.77*10-4 m2/Vs; ion mobility scanning;
  • fLanguage
    English
  • Journal_Title
    Science, Measurement and Technology, IEE Proceedings A
  • Publisher
    iet
  • ISSN
    0960-7641
  • Type

    jour

  • Filename
    210767