• DocumentCode
    887690
  • Title

    DIII-D Timing System

  • Author

    Bramson, Gabriel

  • Author_Institution
    GA Technologies Inc. San Diego, California 92138, U.S.A.
  • Volume
    34
  • Issue
    4
  • fYear
    1987
  • Firstpage
    728
  • Lastpage
    732
  • Abstract
    The DIII-D tokamak, an upgrade of Doublet III, a device to study magnetic confinement fusion at GA Technologies, became operational in February 1986. The new timing system consists of two major subsystems. The trigger subsystem synchronizes control and data acquisition for the experiment. The clock subsystem is a centralized source of pulses for data acquisition equipment. The CAMAC hardware and the database software for the DIII-D timing system is discussed.
  • Keywords
    CAMAC; Clocks; Computer displays; Data acquisition; Databases; Hardware; Magnetic confinement; Synchronization; Timing; Tokamaks;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1987.4334724
  • Filename
    4334724