DocumentCode
889145
Title
Operation of High-Power Cycloconverter-Fed Gearless Drives Under Abnormal Conditions
Author
Pontt, Jorge O. ; Rodríguez, José P. ; Rebolledo, J.C. ; Tischler, Kurt ; Becker, Norbert
Author_Institution
Dept. of Electron. Eng., Univ. of Federico Santa Maria, Valparaiso
Volume
43
Issue
3
fYear
2007
Firstpage
814
Lastpage
820
Abstract
This paper presents the behavior of large power mills (more than 10 MW each) that are fed by cycloconverters. Special attention is dedicated to the protection philosophy to avoid operational interruptions that can produce huge production losses and equipment damage. Several failure possibilities are considered: control failure, complete power outage, if a thyristor fails and cannot block reverse voltage, etc. Simulation studies and field measurements show that large currents and torque can occur under certain circumstances and that motor foundations must be able to support them. As a general conclusion, it can be said that proper protective design effectively avoids equipment damage
Keywords
cycloconvertors; fault diagnosis; motor drives; thyristor applications; equipment damages; failure control; high-power cycloconverter-fed gearless drives; interruption avoidance; power mills; power outage; thyristors; Circuit faults; Industry Applications Society; Milling machines; Power system reliability; Production; Protection; Synchronous machines; Synchronous motors; Thyristors; Voltage control; Cycloconverters (CCVs); gearless drives; mill drives;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.2007.895807
Filename
4215019
Link To Document