• DocumentCode
    889145
  • Title

    Operation of High-Power Cycloconverter-Fed Gearless Drives Under Abnormal Conditions

  • Author

    Pontt, Jorge O. ; Rodríguez, José P. ; Rebolledo, J.C. ; Tischler, Kurt ; Becker, Norbert

  • Author_Institution
    Dept. of Electron. Eng., Univ. of Federico Santa Maria, Valparaiso
  • Volume
    43
  • Issue
    3
  • fYear
    2007
  • Firstpage
    814
  • Lastpage
    820
  • Abstract
    This paper presents the behavior of large power mills (more than 10 MW each) that are fed by cycloconverters. Special attention is dedicated to the protection philosophy to avoid operational interruptions that can produce huge production losses and equipment damage. Several failure possibilities are considered: control failure, complete power outage, if a thyristor fails and cannot block reverse voltage, etc. Simulation studies and field measurements show that large currents and torque can occur under certain circumstances and that motor foundations must be able to support them. As a general conclusion, it can be said that proper protective design effectively avoids equipment damage
  • Keywords
    cycloconvertors; fault diagnosis; motor drives; thyristor applications; equipment damages; failure control; high-power cycloconverter-fed gearless drives; interruption avoidance; power mills; power outage; thyristors; Circuit faults; Industry Applications Society; Milling machines; Power system reliability; Production; Protection; Synchronous machines; Synchronous motors; Thyristors; Voltage control; Cycloconverters (CCVs); gearless drives; mill drives;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2007.895807
  • Filename
    4215019