• DocumentCode
    889615
  • Title

    Effects of magnetic field on pulse and CW operation of the large bore ionized gas laser

  • Author

    Ahmed, Sa´ad Abdirisak

  • Volume
    55
  • Issue
    5
  • fYear
    1967
  • fDate
    5/1/1967 12:00:00 AM
  • Firstpage
    691
  • Lastpage
    692
  • Abstract
    CW and pulse measurement distinguish between ion-drift gas pumping effects [1],[2] and other factors affecting laser output as a function of the confining magnetic field for large diameter (> 5 mm) ionized gas lasers. With pulse lengths too short for pumping to occur laser operation optimizes at 400 gauss, whereas in CW operation the optimum magnetic field may be > 2600 gauss (at low pressures).