• DocumentCode
    890514
  • Title

    Imaging system based on electromagnetic tomography (EMT)

  • Author

    Yu, Z.Z. ; Peyton, A.T. ; Beck, M.S. ; Conway, W.F.

  • Author_Institution
    Univ. of Manchester Inst. of Sch. & Technol., UK
  • Volume
    29
  • Issue
    7
  • fYear
    1993
  • fDate
    4/1/1993 12:00:00 AM
  • Firstpage
    625
  • Lastpage
    626
  • Abstract
    A novel non-contacting instrumentation system for obtaining cross-sectional images of conductive and ferrous material is described. The image space is energised with a parallel magnetic field and the distortion created by objects is detected by sensing coils. The backprojection method is used for reconstruction. Initial results are presented.
  • Keywords
    computerised tomography; image reconstruction; industrial control; EMT; backprojection method; conductive material; cross-sectional images; electromagnetic tomography; ferrous material; imaging system; industrial control imaging; magnetic field distortion; noncontacting instrumentation system; parallel magnetic field; pipelines; reconstruction; sensing coils;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19930418
  • Filename
    211838