• DocumentCode
    890712
  • Title

    Measuring the temperature dependence of resistivity of high purity copper using a solenoid coil (SRPM method)

  • Author

    Nakane, Hiroshi ; Watanabe, Tuneo ; Nagata, Chohjyu ; Fujiwara, Satoshi ; Yoshizawa, Shuji

  • Author_Institution
    Sci. Univ. of Tokyo, Japan
  • Volume
    41
  • Issue
    1
  • fYear
    1992
  • fDate
    2/1/1992 12:00:00 AM
  • Firstpage
    107
  • Lastpage
    110
  • Abstract
    The resistivity of high purity copper was measured by a method which estimates it by using the difference in the impedance between a circular multilayer solenoid coil with a circular rod-shaped copper sample and a similar coil without a copper sample (SRPM method). The residual resistivity ratio (RRR) of high purity copper measured at 100 Hz by the SRPM method has correlated well with the values measured by the DC four-probe method. It was confirmed that an accurate measurement of the resistivity to 10-12 Ωm is possible by the SRPM method. Frequency dependence was confirmed to exist in high purity copper with very low resistivity. As the measuring frequency is raised, the decrease in skin depth seems to affect the resistivity
  • Keywords
    copper; electrical conductivity measurement; solenoids; 100 Hz; Cu; circular multilayer solenoid coil; electrical resistivity measurement; residual resistivity ratio; rod; skin depth; temperature dependence of resistivity; Coils; Conductivity; Copper; Frequency dependence; Frequency measurement; Impedance measurement; Nonhomogeneous media; Solenoids; Temperature dependence; Temperature measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.126642
  • Filename
    126642