DocumentCode :
891534
Title :
Discussion, with reply, on "Assessment of deterioration in epoxy/mica machine insulation" by Y.J. Kim and J.K. Nelson
Author :
Danikas, M.G.
Volume :
28
Issue :
2
fYear :
1993
fDate :
4/1/1993 12:00:00 AM
Firstpage :
303
Lastpage :
305
Abstract :
The commenters raise some questions regarding the measurements reported in the above titled paper (ibid., vol.27, pp.1026-39, October 1992) and their meaning. J.K. Nelson answers some of the questions in terms of the paper´s objectives.<>
Keywords :
ageing; composite insulating materials; filled polymers; insulation testing; machine insulation; mica; partial discharges; ageing; deterioration assessment; dynamic stagnation voltage; epoxy/mica machine insulation; high electric stress; partial discharges; Conducting materials; Conductivity; Conductors; Insulation; Partial discharges; Pulse measurements; Shape measurement; Stators; Stress; Voltage;