• DocumentCode
    892391
  • Title

    High energy electron fluxmeter

  • Author

    Dichter, B.K. ; Hanser, F.A. ; Sellers, B. ; Hunerwadel, J.L.

  • Author_Institution
    Yankee Environmental Systems Inc., Turner Falls, MA, USA
  • Volume
    40
  • Issue
    2
  • fYear
    1993
  • fDate
    4/1/1993 12:00:00 AM
  • Firstpage
    252
  • Lastpage
    255
  • Abstract
    An instrument for measurement of high energy electrons (1-10 MeV) in the Earth´s radiation belts has been designed, calibrated and flown on-board the CRRES spacecraft. The instrument uses a triple coincidence arrangement with two solid state detectors and a BGO scintillator crystal to identify electrons and discriminate against energetic protons. A thorough description of the construction and calibration is presented along with an example of on-orbit data
  • Keywords
    artificial satellites; atmospheric measuring apparatus; calibration; plasma; plasma diagnostic techniques; radiation belts; 1 to 10 MeV; BGO scintillator crystal; CRRES; Combined Release and Radiation Effects Satellite; calibration; construction; high energy electron fluxmeter; magnetosphere; plasma; radiation belts; solid state detectors; triple coincidence arrangement; Belts; Calibration; Detectors; Earth; Electrons; Energy measurement; Instruments; Protons; Solid state circuits; Space vehicles;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.212350
  • Filename
    212350