DocumentCode :
892909
Title :
A High-Accuracy Microwave Phase Standard for Use in Primary Calibration Laboratories
Author :
James, Allan V.
Volume :
16
Issue :
11
fYear :
1968
fDate :
11/1/1968 12:00:00 AM
Firstpage :
944
Lastpage :
949
Abstract :
This paper describes the theory and construction of a broad-band, differential phase shifter for use over the frequency range of from 4.25 to 6.20 GHz. Perturbations of the phase shifter which cause it to deviate from the ideal 2θ operation are discussed. The analysis follows that of Fox, but is carried out in the exponential form, and includes both phase and attenuation constants. A set of nonideal conditions are postulated: improper positioning and matching of the constituent components, improper electrical Iengths of the differential phase shift sections, and loss in the dielectric slabs. Expressions are derived for each of the above conditions that demonstrate the effect on the 2θ operation of the phase shifter. Evaluation of the experimental model shows that it operates within the predicted limits of error, ± 0.5°.
Keywords :
Attenuation; Calibration; Dielectric losses; Frequency; Helium; Laboratories; Phase shifters; Predictive models; Propagation constant; Slabs;
fLanguage :
English
Journal_Title :
Microwave Theory and Techniques, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9480
Type :
jour
DOI :
10.1109/TMTT.1968.1126830
Filename :
1126830
Link To Document :
بازگشت