Title :
7 MHz Particle Identifying PHA
Author :
Spracklen, Howard P.
Author_Institution :
Lawrence Livermore National Laboratory P. O. Box 808 Livermore, California 94550
Abstract :
We have developed a high speed Pulse Height Analyzer (PHA) as a tool for plasma diagnostics using neutron spectra. Histograms of 10 ms duration form time-slice data on plasma buildup and decay. Particle identification, energy digitizing, memory routing, and add-l store can be completed at greater than a 7 MHz rate; acquisition speed is limited by the liquid scintillator.
Keywords :
Capacitors; Delay lines; Detectors; FETs; Neutrons; Pulse circuits; Pulse shaping methods; Shape control; Tail; Turning;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1982.4335985