Title : 
Technical memorandum estmating the residual error from calibrating a reflectometer with a sliding termination
         
        
            Author : 
Griffin, E.J. ; Hodgetts, T.E.
         
        
            Author_Institution : 
Royal Signals & Radar Establishment, Malvern, UK
         
        
        
        
        
            fDate : 
12/1/1987 12:00:00 AM
         
        
        
        
            Abstract : 
A sliding termination is often used to approximate to ¿¿ = 0 when calibrating a reflect-ometer with equivalent generator mismatch ¿¿G. The paper shows that a residual error of ¿¿G*|¿¿T|2 results (where |¿¿T| is the amplitude of reflection from the variable phase load and * denotes complex conjugate) and compares this error with the precision of available calibration standards.
         
        
            Keywords : 
calibration; measurement errors; measurement standards; microwave reflectometry; calibration; calibration standards; complex conjugate; equivalent generator mismatch; reflection amplitude; reflectometer; residual error; sliding termination; variable phase load;
         
        
        
            Journal_Title : 
Microwaves, Antennas and Propagation, IEE Proceedings H
         
        
        
        
        
            DOI : 
10.1049/ip-h-2.1987.0111