DocumentCode :
901418
Title :
Measurement of Transfer Impedance of Thermal Blankets
Author :
van Lint, V.A.J. ; Erler, J.W.
Author_Institution :
Mission Research Corporation 5434 Ruffin Road San Diego, California 92123
Volume :
29
Issue :
6
fYear :
1982
Firstpage :
1601
Lastpage :
1606
Abstract :
EMP and SGEMP induce currents on the outside of spacecraft. The internal fields are determined by the transfer impedance of the satellite skin, which may be metallized dielectrics. The transfer impedance of individual layers of thermal blanket materials and a multi-layer blanket has been measured in a quadraxial test fixture. The inductive component in the transfer impedance is not significant at frequencies up to 300 MHz.
Keywords :
Aircraft manufacture; Dielectric materials; Dielectric measurements; EMP radiation effects; Fixtures; Impedance measurement; Materials testing; Metallization; Satellites; Skin;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1982.4336411
Filename :
4336411
Link To Document :
بازگشت