DocumentCode :
901720
Title :
Chattering conditions in electromagnetic contactors
Author :
Noh, C.J. ; Smith, I.R.
Author_Institution :
Korea Merchant Marine College, Busaw, South Korea
Volume :
127
Issue :
5
fYear :
1980
fDate :
9/1/1980 12:00:00 AM
Firstpage :
324
Lastpage :
328
Abstract :
The chattering of an electromagnetic contactor which may occur when, for example, an induction motor is started direct to line, is studied. Considerations relating to the attractive force of the contactor indicate how a critical voltage may be calculated at which chattering will occur. It is shown that the theoretical voltage obtained this way, is in close agreement with the corresponding measured figure.
Keywords :
contactors; chattering; critical voltage; electromagnetic contactors; theoretical voltage;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings B
Publisher :
iet
ISSN :
0143-7038
Type :
jour
DOI :
10.1049/ip-b:19800042