Title :
Microprocessor-based adaptive water-turbine governor
Author :
Findlay, D. ; Davie, H. ; Foord, T.R. ; Winning, D.J. ; Marshall, A.G.
Author_Institution :
University of Glasgow, Department of Electronics & Electrical Engineering, Glasgow, UK
fDate :
11/1/1980 12:00:00 AM
Abstract :
Conventional governors of water-turbine-generator sets can be set up to provide either stability when supplying an isolated load or rapid response when connected to a large, predominantly thermal, system. In the paper, an adaptive microprocessor-based governor is described which goes some way to satisfying both requirements. Results are given for tests on a 32.5 MW turbine generator.
Keywords :
adaptive control; adaptive systems; computerised control; hydraulic turbines; stability; 32.5 MW turbine generator; adaptive microprocessor based governor; stability; tests; water turbine;
Journal_Title :
Generation, Transmission and Distribution, IEE Proceedings C
DOI :
10.1049/ip-c.1980.0057