Title :
Two-wire bridge-to-frequency converter
Author :
Huijsing, Johan H. ; Van Rossum, Gerard A. ; Van der Lee, Matthijs
fDate :
6/1/1987 12:00:00 AM
Abstract :
An integrated two-wire bridge-to-frequency converter is presented for use as a remote-signal conditioner for sensor bridges such as strain-gauge bridges of platinum-wire temperature-sensing bridges. The converter has a sensitivity on the order of 1 Hz per 1-μV/V relative bridge output. A center frequency of 10 kHz allows the application of an untrimmed bridge with an imbalance up to ±10000 μV/V. The instability is less than 10/SUP -4/ per Kelvin and per 1-V supply-voltage variation. The untrimmed transfer inaccuracy is lower than 1%. The linearity error is lower than 0.01%. Different bridge readout functions can be chosen by different circuit configurations. The converter can be connected to a single supply voltage. The frequency output is modulated on the supply current. The supply voltage is 12-24 V.
Keywords :
Bridge circuits; Electric sensing devices; Signal processing equipment; Strain gauges; Thermometers; bridge circuits; electric sensing devices; signal processing equipment; strain gauges; thermometers; Bridge circuits; Capacitors; Current supplies; Frequency modulation; Operational amplifiers; Pulse amplifiers; Resistors; Switches; Transducers; Voltage;
Journal_Title :
Solid-State Circuits, IEEE Journal of
DOI :