• DocumentCode
    902535
  • Title

    Three-phase pulse-amplitude and width-modulated inverter system

  • Author

    Sriraghavan, S.M. ; Pradhan, B.D. ; Revankar, G.N.

  • Author_Institution
    Tata Electric Company, Research and Development Department, Bombay, India
  • Volume
    128
  • Issue
    3
  • fYear
    1981
  • fDate
    5/1/1981 12:00:00 AM
  • Firstpage
    167
  • Lastpage
    171
  • Abstract
    The proposed 3-phase stepped wave inverter is based on a new method of controlling the double bridge inverter. The control of individual bridges is programmed to yield a stepped voltage waveform with six steps per quarter cycle and a total harmonic distortion of 7.75%. When voltage control is introduced, the proposed pulse-amplitude and width-modulated inverter has predominant harmonics of the 23rd and 25th. The scheme utilises a small number of thyristor power switches operated at low commutation frequency. The results have been experimentally verified.
  • Keywords
    bridge circuits; commutation; electric distortion; harmonics; invertors; pulse amplitude modulation; pulse width modulation; voltage control; PAM; PWM; double bridge inverter; harmonic distortion; pulse amplitude modulated circuits; pulse with modulated circuits; stepped voltage waveform; three phase inverters; thyristor power switches operated at low commutation frequency; voltage control;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings B
  • Publisher
    iet
  • ISSN
    0143-7038
  • Type

    jour

  • DOI
    10.1049/ip-b.1981.0023
  • Filename
    4643355