DocumentCode :
903318
Title :
Design comparison of single-anode and double-anode 300-MW magnetron injection gun
Author :
Lawson, Wes ; Specht, Vicki
Author_Institution :
Dept. of Electr. Eng., Maryland Univ., College Park, MD, USA
Volume :
40
Issue :
7
fYear :
1993
fDate :
7/1/1993 12:00:00 AM
Firstpage :
1322
Lastpage :
1328
Abstract :
Analytic tradeoff equations based on adiabatic assumptions are used to explore feasible design regions for single-anode magnetron injection guns (MIGs). Particle simulations are then used to optimize a single-anode and a double-anode design for a 1-μs, 500-kV, 600-A MIG which is required for a second-harmonic gyroklystron. The advantages and disadvantages of each configuration are critically examined
Keywords :
electron guns; gyrotrons; klystrons; magnetrons; 1 mus; 500 kV; 600 Å; MIG; adiabatic assumptions; design regions; double-anode guns; magnetron injection gun; second-harmonic gyroklystron; single-anode guns; Anodes; Cathodes; Design optimization; Electrodes; Equations; Guns; Klystrons; Numerical simulation; Orbits; Particle beam injection;
fLanguage :
English
Journal_Title :
Electron Devices, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9383
Type :
jour
DOI :
10.1109/16.216439