• DocumentCode
    905164
  • Title

    Calculation of arc-circuit asymmetry in electric-arc furnaces

  • Author

    Ryff, P.F.

  • Author_Institution
    Ryerson Polytechnical Institute, Department of Electrical Engineering Technology, Toronto, Canada
  • Volume
    130
  • Issue
    3
  • fYear
    1983
  • fDate
    5/1/1983 12:00:00 AM
  • Firstpage
    213
  • Lastpage
    217
  • Abstract
    A method is described to determine the arc voltages on a per-phase basis of a 3-phase direct electricarc furnace. Having determined the arc voltages, other arc parameters, such as arc resistance, length and power, can then be obtained. By using the procedure outlined, in conjunction with experimental data on a 100 t, 5¿m diameter shell furnace having a triangulated secondary electrical system, it will be shown that controlling arc powers by means of the impedance control method still results in asymmetric furnace operation. Sample calculations are included, illustrating actual conditions for this furnace.
  • Keywords
    arc furnaces; arcs (electric); arc circuit asymmetry; arc furnaces; arc parameters; arc powers; arc resistance; arc voltages; asymmetric furnace operation; impedance control; length; per-phase basis; power;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings B
  • Publisher
    iet
  • ISSN
    0143-7038
  • Type

    jour

  • DOI
    10.1049/ip-b:19830032
  • Filename
    4643630