DocumentCode
905164
Title
Calculation of arc-circuit asymmetry in electric-arc furnaces
Author
Ryff, P.F.
Author_Institution
Ryerson Polytechnical Institute, Department of Electrical Engineering Technology, Toronto, Canada
Volume
130
Issue
3
fYear
1983
fDate
5/1/1983 12:00:00 AM
Firstpage
213
Lastpage
217
Abstract
A method is described to determine the arc voltages on a per-phase basis of a 3-phase direct electricarc furnace. Having determined the arc voltages, other arc parameters, such as arc resistance, length and power, can then be obtained. By using the procedure outlined, in conjunction with experimental data on a 100 t, 5¿m diameter shell furnace having a triangulated secondary electrical system, it will be shown that controlling arc powers by means of the impedance control method still results in asymmetric furnace operation. Sample calculations are included, illustrating actual conditions for this furnace.
Keywords
arc furnaces; arcs (electric); arc circuit asymmetry; arc furnaces; arc parameters; arc powers; arc resistance; arc voltages; asymmetric furnace operation; impedance control; length; per-phase basis; power;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings B
Publisher
iet
ISSN
0143-7038
Type
jour
DOI
10.1049/ip-b:19830032
Filename
4643630
Link To Document