• DocumentCode
    906043
  • Title

    Characteristics of the Newly Developed MCP and Its Assembly

  • Author

    Matsuura, S. ; Umebayashi, S. ; Okuyama, C. ; Oba, K.

  • Author_Institution
    Hamamatsu Photonics K. K. Ichino-cho, Hamamatsu, Japan
  • Volume
    32
  • Issue
    1
  • fYear
    1985
  • Firstpage
    350
  • Lastpage
    354
  • Abstract
    Several types of MCP assemblies including 2-stage and 3-stage MCPs consist of 8¿m and 12¿m channel MCP having length to diameter ratio ¿ of 40 and 60 are tested relating to the gain and pulse height resolution. The 2-stage assembly with ¿=60 MCPs was incorporated in the proximity type MCP-PMT and showed capability to separate triple photon event clearly. Furthermore, 6¿m channel MCPs in 2-stage was tested in PMT configuration and showed drastic improvement of timing property. As for the life, new MCP showed residual gain of more than 50% at the accumulated output charge of 0.1 C/cm2.
  • Keywords
    Assembly; Electron tubes; Glass; Magnetic properties; Optical imaging; Photonics; Testing; Timing; X-ray detection; X-ray detectors;